Investigation of Switch-Off Transients of Cathodic Protection in High-Temperature Media
DOI:
https://doi.org/10.33927/hjic-2026-36Keywords:
cathodic protection, transient depolarization, elevated temperature, soil corrosion, potential criterionAbstract
Corrosion is the undesirable physicochemical transformation and degradation of structural materials caused by environmental factors. Cathodic protection is a widely used method to mitigate corrosion of steel structures, but its applicability is limited by specific operational conditions, such as extreme temperatures. This study investigates the effectiveness of cathodic protection at elevated temperatures, utilizing a novel experimental methodology to evaluate switch-off transients. Measurements were carried out in liquid and sand media at 80 °C with varying concentrations of NaCl, Na2CO3, and Na2S. The results indicate that a system remains cathodically protected even at elevated temperatures if the ohmically compensated polarization is at least -100 mV relative to the calculated corrosion potential. Furthermore, the calculated corrosion current drops by orders of magnitude when the cathodic Tafel slope decreases below 20 mV, providing another control parameter for the effectiveness of the protection.